| Technical Data |
| Dimensions |
81 mm x 50 mm x 28 mm (WxHxD) |
| Weight |
76 g
|
| Temp. range |
H2S: -40 °C to +50 °C;
CO: -40 °C to +50 °C;
O2: -35 °C to +50 °C |
| Humidity |
5 % to 95 % non-condensing relative humidity
|
| Alarms |
Visual, vibrating, audible (minimum 95dB)
|
| LED’s |
LEDs on top, front and side
|
| Display |
Alphanumeric LCD Graphics display
|
| Tests |
Full function self-test on activation and every 20 hours,
continuous automatic battery tests |
| Operational Life |
2 years, at 4 alarm minutes per day
|
| Protection type |
IP 66/67
|
| Certifications |
ATEX II 1G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4
|
| Warranty |
2 years from activation
1 year shelf life |
| Gases |
H2S 0 - 100 PPM
CO 0 - 300 PPM
O2 0 - 30 % |
| Optional accessories |
Esders IR communication module communicates directly with the Single Gas to program special alarm set points, user options, as well as, download event logs & data logs
|