Technical Data |
Display |
Illuminated LCD Graphics display with 128 x 64 Pixel + special sign
|
Power Supply |
rechargeable EX NiMH-battery 4.8 Volt
|
Operating time |
workplace monitoring > 10 hours (without illumination)
|
Measurement range |
0-10,000 ppm methane, resolution 1, 10, 50, 100 ppm
0 to 50 % LEL methane, resolution 0.5% LEL
0 to 100 Vol.% methane, resolution 0.1 Vol.%
optional: Pressure 0 to 200 hPa, resolution 0.1 mbar
optional: Propane calibration |
Alarm |
Acoustic and optical alarm signal
|
Operating temperature |
- 20 °C to + 50°C
|
Dimensions |
190 x 58 x 34 mm
|
Weight |
approx. 475 g battery included
|
Protection |
BVS 05 ATEX E 010 X Ex ib d IIB T3 Gb |