Models |
Pundit Live Array Pro
|
Pundit Lab(+)
|
Pundit 200
|
Pundit 200 Pulse Echo
|
Pundit 250 Array
|
Descriptions |
The wireless Pundit Live Array Pro tomography scanner is connected with an iOS app to an Apple® iPad. It comes with Artificial Intelligence (A.I.) user support and 3D imaging capabilities. |
The Pundit Lab is a flexible UPV test instrument designed primarily for operation in laboratories. It supports all traditional UPV test modes. The Pundit Lab+ comes with an extended feature set. |
The Pundit 200 is a best-in-class UPV test instrument with an extended range of measurement modes. Rugged touchscreen with intuitive user interface for best possible measuring and analysis of the measured data. |
The Pundit 200 Pulse Echo extends the ultrasonic application to objects where access is restricted to a single side. Major applications are slab thickness measurments and the location of voids and delaminations. Rugged touchscreen with intuitive user interface. New: Pundit® Dry-Point Shear Wave Transducer |
The Pundit 250 Array is a modular phased array pulse echo instrument incorporating dry-point contact transducers. It features unique real time B-Scans as well as on-site C-scans, P-scans and Volume scans. |
Your Benefits |
Smart A.I. user support and positioning
|
Automated combination of the transmitter voltage and the receiver gain for accurate and stable measurements
Open interface, can be integrated into LabView
Pundit Lab+ removes the need for external amplification when used with exponential transducers
|
Various measurement modes including Line Scan, Area Scan, Data Logging, compressive strength correlations and E-modulus measurement
Automatic surface velocity calculation according to standards
Same instrument can be used with pulse echo transducers
|
B-Scan is constructed directly on the instrument as the scan is carried out
Can be upgraded to Multi Channel
Same instrument can be used with classic pulse velocity transducers
|
Full modular system allows to increase the number of channels by simply attaching additional probes
Unique real-time B-scan and panorama B-scan
Same instrument can be used with classic pulse velocity transducers
|
Measuring Range |
>1 m depending on concrete quality |
Up to 15 m depending on concrete quality |
Up to 15 m depending on concrete quality |
Up to 1 m depending on concrete quality |
Ca. 1m depending on concrete quality |
Bandwidth |
15 to 100 kHz |
20 to 500 kHz |
20 to 500 kHz |
20 to 500 kHz |
20 to 500 kHz |
Technology |
Phased array ultrasonic pulse echo |
Ultrasonic pulse velocity |
Ultrasonic pulse velocity |
Single channel ultrasonic pulse echo |
Phased array ultrasonic pulse echo |
Measuring Resolution |
1 μs |
0.1 us |
0.1 us |
0.1 us |
0.1 us |
Plus Voltage UPV |
– |
125 to 500 V |
100 to 450 Vpp |
– |
– |
Plus Voltage UPE |
±150 V |
– |
– |
± 50 to ± 200 V |
+/- 150 V |
Receiver Gain |
1 to 10’000x (0 to 80 dB) |
1x, 10x, 100x, AUTO, Pundit Lab+ up to 1000x |
1 to 10’000x (0 to 80 dB) |
1 to 10’000x (0 to 80 dB) |
1 to 10’000x (0 to 80 dB) |
Nominal transducer frequency |
50 kHz shear wave |
24 – 500 kHz |
24 – 500 kHz |
24 – 500 kHz |
50 kHz shear wave |
Pulse Shape |
Square wave |
Square wave |
Square wave |
Square wave |
Square wave |
Pulse Delay |
8 ms – 200 ms |
– |
– |
– |
8 ms – 200 ms |
Number Of Channels |
8 (with upgrade option to 16) |
1 |
1 |
1 |
8 (with upgrade option to 16) |
Applications |
|
|
|
|
|
Pulse velocity determination |
x |
√ |
√ |
√ |
x |
Quality assessment and uniformity |
√ |
√ |
√ |
√ |
√ |
Compressive strength estimation |
x |
Pundit Lab+ only |
√ |
x |
x |
SONREB |
x |
Pundit Lab+ only |
√ |
x |
x |
Modulus of elasticity measurement |
x |
√ |
√ |
x |
x |
Curing status evaluation |
x |
√ |
√ |
x |
x |
Thickness measurement from a single side |
√ |
x |
x |
√ |
√ |
Crack depth estimation |
x |
√ |
√ |
x |
x |
Location of delaminations, voids and honeycoming |
√ |
x |
x |
√ |
√ |
Location of hollow pipes |
√ |
x |
x |
√ |
√ |
Location of pipes and tendon ducts beyond the rebar layer |
√ |
x |
x |
√ |
√ |
Assessment of fibre reinforced concrete |
√ |
√ |
√ |
√ |
√ |
Additional Applications |
|
|
|
|
|
Features |
|
|
|
|
|
Instrument Firmware |
- High resolution imaging of thickness variations, delaminations, voids and tendon ducts
- Cursors for depth and horizontal displacement information
- Settings directly accessible on measuring screen
- AI positioning system
- Automatic back wall detection
- Automatic pulse velocity estimation
|
- Open interface
- Integrated amplifier gain stage (Pundit Lab+ only)
- Real time stamp (Pundit Lab+ only)
|
- Zoom and scroll for precise A-Scan inspection
- On board storage and review of waveforms
- Settings directly accessible on measuring screen
- Dual cursor for manual A-Scan evaluation
- Separate cursor to measure signal amplitude
- Automatic and manual triggering and user adjustable trigger threshold
- A-Scan update rate up to 25 Hz
|
- Gate function
- Raw data export
- Settings directly accessible on measuring screen
- Advanced echo tracking technology helps identifying the main echo
- Automatic estimation of the Pulse Velocity
|
- Raw data export
- Settings directly accessible on measuring screen
|
PC Software |
Browser-based live.proceq.com webtool |
Pundit Link unlocks the full Pundit Lab+ capabilities |
PL-Link for analysis and export data to third party applications |
PL-Link for analysis and export data to third party applications |
PL-Link for analysis and export of data to third party applications |
Display |
Any compatible Apple® iPad (iOS 9.0 and higher) |
79 x 21 mm passive matrix OLED |
7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor |
7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor |
7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor |
Memory |
Up to 512 GB (depending on the Apple® iPad model) |
> 500 measured values |
Internal 8 GB flash memory |
Internal 8 GB flash memory |
Internal 8 GB flash memory |
Connections |
Wi-Fi connection to Apple® iOS tablet, USB port for Wi-Fi module |
USB connection to PC |
USB host / device and Ethernet |
USB host / device and Ethernet |
USB host / device and Ethernet |
Measurement Modes |
|
- Pulse velocity
- Surface velocity
- Data logging
- E-modulus
- Compressive strength correlation (Pundit Lab+ only)
- Crack depth
|
- Pulse velocity
- Surface velocity
- Data logging
- E-modulus
- Compressive strength correlation
- Crack depth
- Line Scan
- Area Scan
|
- Pulse velocity
- Area Scan
- A-Scan
- B-Scan
- Distance
|
- Real time B-Scan
- Panorama B-Scan
|
Transducers |
Rugged, compact and lightweight Pundit Array Transducer. Standard: Single handed transducer. Dual handle upgrade for increased control (buttons on both handles, optimize gain settings and trigger a measurement). Upgrade to 16 channels for double the scan width |
- Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave
- Connect third party transducers up to 500 kHz with BNC connector
|
- Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave
- Connect third party transducers up to 500 kHz with BNC connector
|
- Dry-contact Pundit Pulse Echo transducer with control buttons, optical feedback, center marker and rulers for easy B-Scan measurements
- Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave
- Connect third party transducers up to 500 kHz with BNC connector
|
|
Standardization |
|
|
|
|
|
Standards |
|
- EN 12504-4
- ASTM C 597-02
- ISO 1920-7:2004
- IS 13311
- CECS 21
- ГОСТ 17624
|
- EN 12504-4
- ASTM C 597-02
- ISO 1920-7:2004
- IS 13311
- CECS 21
|
|
|
Guidelines |
- RI-ZFP-TU
- FCC Part 15: 2010
- Class A Digital Device
|
|
|
|
|
Accessories |
|
|
|
|
|
Measurement Accessories |
- Upgrade to 16 channel: Pundit Array Transducer (327 30 100), Pundit Array Transducer Extension Kit (376 30 377) and Dual Handle Kit (327 30 370)
- Upgrade to dual handle: Dual Handle Kit (327 30 370)
- Pundit Array Transducer Battery Pack Complete (327 30 337)
- Rechargeable AA NiMH battery set of 6 (327 30 384S)
- Calibrated tape set of 5 (327 01 071S)
|
- 2 S-Wave Transducers, 250 kHz, incl. couplant (325 40 049)
- 2 Exponential transducer 54 kHz, including calibration rod (325 40 176)
- Transducer 150 kHz (Two required for operation) (325 40 141)
|
- 2 S-Wave Transducers, 250 kHz, incl. couplant (325 40 049)
- 2 Exponential transducer 54 kHz, including calibration rod (325 40 176)
- Pundit Pulse Echo Transducer, incl. cable, contact tester and documentation (327 40 130)
- Upgrade Kit to Pundit 250 Array (327 30 130)
- Battery complete (327 01 033)
- Quick Charger (external) (327 01 053)
|
- Pundit® Dry-Point Shear Wave Transducer
- Upgrade Kit to Pundit® 250 Array (327 30 130)
- 2 S-Wave Transducers, 250 kHz, incl. couplant (325 40 049)
- 2 Exponential transducer 54 kHz, including calibration rod (325 40 176)
- Battery complete (327 01 033)
- Quick Charger (external) (327 01 053)
|
|